ÈËÉú¾ÍÊDz«

NTEKÈËÉú¾ÍÊDz«¼ì²â¼¯ÍÅ

Ä¿½ñλÖà : Ê×Ò³ > ÐÂÎÅ×ÊѶ> ÐÐҵ֪ʶ

CEÈÏÖ¤SAR²âÊÔ±ê×¼ÖØ´ó±ä»»Ô¤¾¯

2019-11-27
8320 ×÷Õߣº ÈËÉú¾ÍÊDz«¼¯ÍÅ

CEÈÏÖ¤SAR²âÊÔ¸ÅÊö

       SAR²âÊÔÊÇÖ¸µç´Å²¨ÎüÊÕ±ÈÖµ»ò±ÈÎüÊÕÂÊ£¬£¬ÔÚCEÈÏÖ¤Öбê×¼½ÓÄÉÏÞÖµ±ê×¼

       EN 50360-2001 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields(300 MHz ¨C 3 GHz)²úÆ·±ê×¼

       EN 50566©\2013 Product standard to demonstrate compliance of radio frequency fields from hand held and body-mounted wireless communication devices used by the general public (30 MHz -- 6 GHz)ÊÖÒÕ±ê×¼

       EN 62209-1-2006 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication  devices ¡ª Human models, instrumentation, and procedures ¡ªPart 1: Procedure to determine the specific absorption rate (SAR) for  hand-held devices used in close proximity to the ear (frequency range  of 300 MHz to 3 GHz)

       EN 62209-2-2010 Human exposure to radiofrequency fields from hand-held and body mounted wireless communication devices ¡ª Human models, instrumentation, and procedures Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body(frequency range of 30 MHz to 6 GHz) 

       EN 62479-2010 Assessment of the compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz)

       ÆäÖУ¬£¬ÊÖÒÕ±ê×¼EN 62209-2-2010×÷Ϊ²úÆ·±ê×¼EN 50566©\2013µÄÊÖÒչ淶ÐÔÎļþ£¬£¬½ç˵body SAR¼ì²â¾àÀ룬£¬ÓɲúÆ·ÖÆÔìÉÌÆ¾Ö¤½ç˵Æä²úÆ·Ô¤ÆÚʹÓõĵ䷶¾àÀë¡£¡£¡£ÈçÊÖ»úÀ࣬£¬ body SAR¿É½ç˵²¢½ÓÄÉ10 mm/ 15 mm×÷ΪÆÀ¹À¾àÀë¡£¡£¡£

±ê×¼ÖØ´ó±ä»»        

       2014Ä꣬£¬·¨¹ú¶Ô±ê×¼EN 50566©\2013Ìá³öÒìÒ飬£¬Ö¸³öӦ˼Á¿±ãЯºÍÒÆ¶¯Ê½²úÆ·µÄÏêϸʹÓÃÌõ¼þ£¬£¬²¢Ó¦Ìá³öbody SAR µÄÆÀ¹À¾àÀë¡£¡£¡£Å·Ã˾­ÓÉÆÀ¹ÀºóÒÔΪ¸ÃÌáÒéºÏÀí£¬£¬Ðè¶ÔEN50566¾ÙÐÐÐÞ¶©Ôö²¹£¬£¬ÄÚÈÝÈçÏ£º    

       ¾¯Ê¾:»ùÓÚÇå¾²ÐÔÄ¿µÄ,Á¬ÏµÖ¸Áî1999/5/ECµÄArticle 3(1)(a)Ìõ¿îÒÔ¼°¸½¼þI ÖÁÖ¸Áî2006/95/ EC£¬£¬»®¶¨ÔÚʹÓô˲âÊÔ±ê׼ʱӦÇкÏÏà¹Ø¾àÀë¾àÀëµÄ»®¶¨£¬£¬²¢ÄÜ·´Ó¦³ö×°±¸ÏÖʵһÑùƽ³£Ê¹ÓÃʱµÄÕæÕæÏàÐΣ¬£¬È·±£¹«ÖÚÔÚʹÓã¨30MHz£­6GHz£©ÊÖ³ÖʽºÍÉíÌåÅå´øÊ½ÎÞÏßͨѶװ±¸Ê±µÄÇå¾²ÐÔ¡£¡£¡£ ¾ÙÀý˵Ã÷£¬£¬¹ØÓÚÖ«ÌåSARÆÀ¹À£¨ÏÞֵΪ4W/kg£©£¬£¬ÕÉÁ¿¾àÀë¾àÀëΪ0£¨×°±¸Ö±½Ó½Ó´¥Ä£×Ó£©£»£»£»£»£»¹ØÓÚÉíÌåbody SAR£¨ÏÞֵΪ2W/kg£©£¬£¬ÕÉÁ¿¾àÀë¾àÀë¿ÉÒÔÊǼ¸mm¡£¡£¡£ ¡¾Warning: The application of this publication shall observe certain conditions relating to the separation distance, reflecting the practical day to day use, ensuring the safe use of handheld and body©\mounted wireless communication devices used by the general public (30 MHz ©\ 6 GHz), for the purposes of the safety objectives provided for in Article 3 (1) (a) of Directive 1999/5/EC, in conjunction with Annex I to Directive 2006/95/EC. For example, for limb SAR measurements (limit 4 W/kg), no separation distance may be used (device in contact); for trunk SAR measurements (limit 2 W/kg) a separation distance of less than a few millimetres may be used.¡¿     

       ¾ÝϤ£¬£¬Å·Ã˽«ºÜ¿ÉÄÜÔÚ½üÆÚ£¬£¬¼´2016ÄêÖУ¬£¬ÍÆÐУºÖ«ÌåSARÕÉÁ¿£¨ÏÞֵΪ4W/kg£©£¬£¬ÕÉÁ¿¾àÀë¾àÀëΪ0£»£»£»£»£»body SAR£¨ÏÞֵΪ2W/kg£©£¬£¬ÕÉÁ¿¾àÀë¾àÀëΪ5mm¡£¡£¡£Òò´Ë£¬£¬¹ØÓÚ½üÆÚÍýÏ뿪չŷÃËSAR¼ì²âµÄÏîÄ¿ÁÐλÈÏÕæÈË£¬£¬Í¬Ò«ÊµÑéÊÒÌØÊâÌáÐÑ£ºÇëÌáǰ×Ðϸ×öºÃÑз¢ÆÀ¹À£¬£¬×èÖ¹ÔÚÈÏ֤ʱ·ºÆðfail£¬£¬¶øÊ¹Õû¸öÈÏÖ¤ÖÜÆÚÁè¼Ý¿ØÖƹæÄ£¡£¡£¡£

       ÒÔÏÂÊÇʵÑéÊÒ»®·ÖÑéÖ¤15mm/10mm/5mm/0mm Body SARËù»ñµÃµÄÒ»×éÊý¾Ý£¬£¬¹©²Î¿¼¡£¡£¡£                                                                         


Á¬Ã¦×Éѯ »ñÈ¡±¨¼Û

»ñÈ¡±¨¼Û

¹«Ë¾Ãû³Æ£º *
ÄúµÄÐÕÃû£º*
ÄúµÄÊÖ»ú£º*
ÄúµÄÐèÇó£º*

*ΪÁËÄú µÄÈ¨Òæ£¬£¬ÄúµÄÐÅÏ¢½«±» ÑϿᱣÃÜ

ÐÅÏ¢Ìá½»ÀÖ³É

רҵ¹¤³Ìʦ½«·É¿ìÁªÏµÄú£¬£¬ÎªÄúÌṩºÏÊÊ ½â¾ö¼Æ»®£¬£¬ÆÚ´ýÓëÄúÏàÓö~

΢ÐŹ«ÖÚºÅ
·ÖÏíÐÐÒµ¸É»õ
΢ÐÅ×Éѯ
Ç뱸ע×ÉѯЧÀÍ
¡¾ÍøÕ¾µØÍ¼¡¿